| Standard |
Type
of immunity |
Test
Specification |
Application |
Level |
|
IEC61000-4-2
EN61000-4-2 |
Electrostatic
discharge |
6kV contact
discharge
8kV air discharge |
Module
enclosure |
Level 3
(industrial) |
|
IEC61000-4-3
EN61000-4-3 |
Radio
frequency
radiated field |
10V/m prior to
modulation
80 - 1000MHz
80% AM (1kHz)
modulation |
Module
enclosure |
Level 3
(industrial) |
|
IEC61000-4-4
EN61000-4-4 |
Fast transient
burst |
5/50ns 2kV
transient
at 5kHz repetition
frequency via
coupling clamp |
Control
lines |
Level 4
(industrial
harsh) |
|
5/50ns 2kV
transient
at 5kHz repetition
frequency by direct
injection |
Power
lines |
Level 3
(industrial) |
|
IEC61000-4-5
EN61000-4-5 |
Surges |
Common mode 4kV
1.2/50μs
waveshape |
AC supply
lines:
line to earth |
Level
4 |
|
Differential mode
2kV
1.2/50μs
waveshape |
AC supply
lines:
line to line |
Level
3 |
| Lines
to earth |
Signal ports
to earth 1 |
Level
2 |
|
IEC61000-4-6
EN61000-4-6 |
Conducted
radio
frequency |
10V prior to
modulation
0.15 - 80MHz
80% AM (1kHz)
modulation |
Control and
power lines |
Level
3
(industrial) |
|
EN50082-1
IEC61000-6-1
EN61000-6-1 |
Generic immunity
standard for the
residential, commercial and light -
industrial environment |
|
Complies |
|
EN50082-2
IEC61000-6-2
EN61000-6-2 |
Generic immunity
standard for the
industrial environment |
|
Complies |
|
EN61800-3
IEC61800-3
EN61800-3 |
Product standard for
adjustable
speed power drive systems
(immunity requirements) |
Meets immunity
requirements for first and
second environments |
|
IEC61000-4-11
EN61000-4-11 |
Voltage dips
and
interruptions |
-30% 10ms
+60% 100ms
-60% 1s
<-95% 5s |
AC power